Pre-manufactured light prefabricated structural characteristics of the external and internal walls 10 cm FRAMEWORK PANEL (Fibercement + EPS + Fibercement)
EXPLANATION; Production system with seamless construction technology, pre-manufactured light prefabricated buildings, according to the intended use of the width and length of 125 cm so that the layers can be applied to any desired layout. Panel dimensions 1250 * 2500 mm'dir.ö the manufactured light prefabricated buildings to be suitable for multiple installation and dismantling has been designed. All architectural planning, design and technical drawing ARCHICAD 9 GB, STRUCAD (Structural Steel Detailing System Version-16) and AutoCAD, Sta4CAD, with ÇELİKPROIV programs, engineering calculations SAP 2000 is carried out by our technical staff with the CFS program. All materials used are certified by TSE. TECHNICAL DATA Snow load 80 kg / m - TS 498 and TS EN 1991-1-3 Wind speed 102 km / h (50 kg / m²) TS 498 and TS EN 1991-1-4 External wall heat transfer coefficient K: 0.37 kcal / m² hc (F: 0.43 W / m K) Interior wall heat transfer coefficient K: 0.36 Kcal / m²hC (K: 0.42 W / m K) Roof heat transfer coefficient K: 0.39 Kcal / m²hC (K: 0.45 W / m K) Chassis load capacity of 200 kg / m² (for two storey building) T.S 498 (T.S according to the purpose and type of building by 498 200/350/500 Kg / m2 may be.) Earthquake zone Effective ground acceleration coefficient: o = 0.40 (1st degree earthquake zone) Building Importance Factor (I = 1) Live Load Participation Factor (n = 0,3) According to the purpose and type of building I = 1 / 1.2 / 1.4 / 1.5, n = 0.3 / 0.6 is calculated. RELATED STANDARDS DESIGN-STATIC: EN 1993-1-1, 1-2, 1-8 + AC, (EUROCODE 3), TS 11372, TS 498, TS 648, TS 6793, TS EN 1991-1-1-3, 1-1-4 (EUROCODE 1), EN 1998-1 (EUROCODE 8), IMO- 01.-01/2005, Things About Buildings in Earthquake Zones regulations - 2007 PANEL CARCASS, SCISSORS, FALLING STEEL CONSTRUCTION: Material: DX51D + Z (~ St 37) Erdemir quality no 1311, S250GD + Z Erdemir quality no 1325, S320GD + Z Erdemir Quality No. 1332, S350GD + Z (~ St 52) Erdemir Quality No. 1335, DIN EN 10346-00 zinc coated galvanized steel structure Production: EN 10162 and in accordance with the standard JIT production system pulled from the machine galvanizing C / sectioned cold formed profiles from 0.8 to 2 mm thickness and 40-300 mm web width. Combination of elements: Clinch nut, galvanized bolts, nuts DIN 960-961 DIN 935- F, 8.8 Thermal insulation: Thermal Insulation Regulations (8.05.2000) Soundproofing: TS 187 and TS 854 (DIN 4109) Fire Resistance: TS 1263, DIN 4102, EN 13501-1, Regulation on Fire Protection of Buildings - 2002 Wall insulation 3 climatic zones Climate Region (K: 0.50 W / m K) is appropriate. Roof insulation 1 ~ 2.ikl district (K: 0.40 W / m² K) is appropriate. BASIC ARKE GROUP concrete plans will be given by Structure (basic dimensions) suitable concrete has to be done, design, structural, foundation and flooring determined using anchorages and dowel to the concrete floor by the EMPLOYER has ground on the anchored raft should be prepared basic foundation or steel mesh. EXTERIOR AND INTERIOR WALLS Panel height 2537 mm Wall dimensions / thickness 1250x2537x100 mm 1250x2500x100 mm Exterior Wall Surface 8 mm fiber cement flat sheets - (Fireproof) class A1 Internal Wall Surface 8 mm fiber cement flat sheets - (Fireproof) class A1 Insulation 80 mm thick polystyrene foam (EPS) - the fire class B1 (16 kg / m3) 1/3 Panel carcass Vertical Records 84x50x1,2 / 1.0 mm galvanized rollform pulled from the machine to a high standard C / sectioned cold formed profiles (static calculations and designs according to the requirements of 0.8 - can be changed from 2 mm.) EPS material panels for the lack of heat loss is inserted into the frame. ROOF whole venue Fibercement 8 mm sheet - (Fireproof) class A1 80 mm mattress glass wool insulation (rock wool ceiling is used as an option.) ROOF Depending on demand and climatic conditions Coating metal tile, shingle, painted galvanized or corrugated sheets are used or liter or a liter of interior sing the us Angle omega-section (80x50x0,9 mm) galvanized rolled coils from the machine roll former cold formed profiles Scissor 125cm galvanized coils made of a high standard with specially designed scissors intermediate the outer and inner profiled steel scissors. (Sheet thickness according to static calculation and construction of the required 0.8 - ranged from 2 mm.) 150x300 mm PVC vent in the spring and the outside for ventilation. Fringe 20 cm PVC eaves. 150x150 mm PVC vent in the eaves to prevent sweating. PVC or galvanized steel gutters streams and creeks application can be made optional DELIVERY SYSTEMS S350GD + Z (1335), quality (~ St52) or DX51D + Z (1311), quality (~ ST37) galvanized pulled from the roll former machine coils panel carcass, mezzanine chassis consists of a cross with roof trusses and purlins. Static calculations result in varying thickness and width of the required profile or industry profiles and DKP / Galvanized column beam reinforcement and supply / screws / bolts can be used. WALL JOINTS The United bolts and nut connected and building walls, the walls of the United Sealing internal structure of PVC H profiles are used. CEILING JOINTS 8 mm Fibercement ceiling material, galvanized omega sheet, painted aluminum T profile (P a s v e t rl m e t d n s p e k in the interior) are combined using a combination of elements. ACCESSORIES Zorez, board omega-top, take the edge coating material, scissors taken cladding material, window subframe, under the eaves of pvc coating. (Rust and to prevent sweating) NOTE: Edge omega, eaves, window subframe, galvanized sheet received by the static of buildings and structures are made of steel. 1st FLOOR FRAME AND LADDERS (The building consists of two floors) Chassis: Rollform taken at machinery galvanized C / sectional profile bearings buildings are produced in the thickness required by the static. (Cold form S320GD + Z / S350GD + Z, Erdem 1332/1335, DX51D Erdemir 1311 quality + Z) The floor covering is 16 mm thick fiber cement panels. (Fireproof) class A1 Optionally, the plate glass wool insulation is between the frame. Optionally risers or risers hollow spaces wood or metal ladders are used EXTERIOR AND INTERIOR DOORS External door frame 1 mm RAL 9002 painted galvanized sheet, seamless Residential: Box external dimensions 900/1970 mm aluminum door (steel door is used as optional) Internal door frame 1 mm RAL 9002 painted galvanized Sheet metal, seamless External dimensions 840/1960 mm press-lam MDF doors (wooden carcass, craft filled) wing thickness: 42 mm (American door is used as optional.) Wet door External dimensions 720/1960 mm press-lam MDF doors (wooden carcass, craft filled) wing thickness: 42 mm (optional aluminum door, PVC door is used.) Door lock and handle external and internal door lock cylinder lock (housing interior door locks embedded), door handles, yellow or gray colored metal door handle. WINDOW FRAMES Window (PVC cased) 830/1190 mm PVC Sleeve Transom (PVC cased) 830/400 mm PVC Sleeve GLASS Double glazing 4 + 9 + 4 mm - Silicone-based external paint exterior 2x 2/3 PAINT Interior walls 2 layers of plastic based interior paint - Other Galvanized cold form truss, love, the panel frame is unlined mezzanine chassis seamless technology is used. Note: delivery no later than one week before the paint color bildirilmelidir.aks by the customer, the standard paint colors will be sent. Galvanized metal parts outside the outer surface: 1 layer rapid primer + 2 layers oil staining ELECTRICAL INSTALLATION Recessed or surface mounted Cable (NYM 220 V, 50 Hz.) PVC conduit (16 mmx25 mm) in ANTIGRON cable outlet sorties 3X2.5 mm² NYM Socket Socket Lines 4.times.2.5 mm² NYM cable Lighting sorties 2x1.5 mm² NYM Lines 3X1,5 mm² NYM cable, Fluorescent Lighting Fixtures normal space Bagels (for housing) -1 * 2 * 36 W 36 W 18 W -1 * 2 * IAS 18 W fluorescent luminaire Fluorescent wet areas Globe - IP 44, Door light sockets, switches Fuse box W Insurance Insurance vending boxes Electrical panels, Low-voltage devices (phone, TV, data), the main Employers will be made by the company. PLUMBING Flush or higher plaster Sanitary Ware / Fixtures Sinks 45 * 55 cm. pedestal sink The sink and shower faucets cold water installation lavatories and faucets, wall-mounted hot water installation lavatories and taps output from the sink Toilet ceramic cistern closet Alaturka move HeLa (bidet nozzles Shower tray 80 cm cmx80 Kitchen sink 50/100 cm chromium material, yapılmaktadır.üst my closet double cabinets chipboard yapılmamaktadır.100 cm sink cabinet. Pure Water Pipes Waste water PPRC - PVC - |